BPM-ES404 Electrosurgical Metal Cautery Unit Portable High Frequency Bipolar Electrosurgical Unit

1.0 Units
MOQ
BPM-ES404 Electrosurgical Metal Cautery Unit Portable High Frequency Bipolar Electrosurgical Unit
特徴 ギャラリー 製品の説明 見積依頼
特徴
仕様
Model Number: BPM-ES404
Power Source: Electric
Warranty: 1 Year
After-sale Service: Onsite Training
Material: Metal
Shelf Life: 1years
Quality Certification: CE,ISO
Instrument classification: Class II
Safety standard: 60601
Model: BPM-ES404
Name: Electrosurgical Unit
Environmental temperature range: 5 C~40 C
Atmospheric pressure range: 86.0-106.0 kpa
Power supply: 220V (+22V), 50Hz (+1)
Working frequency: 360-460 kHz
Relative humidity range: <80
Type of equipment: CF
Rated power of equipment: 880 VA+10%
Keywords: Electrosurgical Unit
基本情報
証明: CE,ISO
Model Number: BPM-ES404, BPM-ES404
お支払配送条件
製品の説明
Product Information

BPM-ES404 Diathermy Machine Cart For Dental Bovie Erbe Bipolar Electrosurgical Unit

Features

1.With memory function, it remembers last used power setting
2.With a neutral electrode contact quality inspection system that can detect plate contact area,the system real-time detection and effective assessment of the plate and the skin contact area, contact area if it is found down to a dangerous level. the system automatically cut off the out put and alarm.
3.Large high-definition digital display
4.Host has an automatic monitoring and error show function.
5.Type of equipment: CF type
6.Cutting: Pure cutting, the effect of which is fine cutting, fresh tissue surface without scab:
7.Blend cut 1: The effect is that the cutting has slight coagulation effect:
8.Blend cut 2:lts effect is to provide powerful coagulation effect while cutting:
9.Electrocoagulation 1: It can be called soft electrocoagulation or spot coagulation, which has a relatively deep coagulation laver and a relatively small scope of action, and can be used with endoscope:
10.Electrocoagulation 2: It can be called strong electrocoagulation or surface coagulation, which is relatively fast and has a large area of action;
11.Bipolar Coag It can be called fine bipolar electrocoagulation. It can quickly achieve the coagulation effect at the start-up moment, automatically cut off the power output during tissue coagulation, achieve excellent coagulation effect, and effectively prevent tissue adhesion;

Technical parameters

Environmental temperature range

5 C~40 C

Relative humidity range

<80

Atmospheric pressure range

86.0-106.0 kpa

Power supply

220V (+22V), 50Hz (+1)

Working frequency

360-460 kHz

Rated power of equipment

880 VA+10%

Type of equipment

CF

The power consumption of the whole machine is less than 1000VA